Druck Unomat TRXII Product Details…

The Druck TRX II portable documenting calibrator is the culmination of many years of combined field experience with the Druck and Unomat series of calibrators.

This one self-contained, battery powered package simulates and measures RTD’s, thermocouples and resistance, as well as sourcing and reading milliamps, millivolts, volts and frequency.

The rugged design includes an impact resistant enclosure which is fastened to the carrying case for convenience and safety. Dedicated alphanumeric and documenting keypads surround a large LCD panel with dual readout and backlight. Connectors for source and measure are kept separate and a 24V output is provided for loop power. The TRX II’s extensive measurement capabilities can include pressure measurement by connecting Druck pressure sensors which have been digitally characterized to give high accuracy.

This highly accurate and easy to use documenting calibrator provides improved data quality and quicker calibration time since data can be uploaded and downloaded via the PCMCIA card or the RS232 interface

Features and Benefits…

  • Simulates and Reads RTD’s and thermocouples
  • Sources and reads Millivolts, Volts, Milliamps, Ohms and frequency
  • Measures pressure -14.7 to 10,000 psi
  • Dual readout: measure and source
  • Data storage for field calibrations
  • Data transfer via RS 232 or PCMCIA card
  • Menu driven software with help screen
  • Data storage: Internal 4Mbyte memory
  • Up to 9 user defined sequences can be stored and recalled by a single key stroke
  • mA measurement; typical accuracy 0.01% reading
  • mV / Voltage measurement typical accuracy 0.025% reading
  • 2 wire temperature sensor output can be displayed in mA or temperature units (°C or °F)
  • 2, 3 or 4 wire RTD's detected automatically
  • Fully programmable ramp or step output functions
  • Loop power 12Vdc
  • Switch test captures value at status change
  • Robust IP53 housing
  • Certified to II 2(1) G EEx ia IIC T5, certificate no. KEMA 03 ATEX 1037X
  • Current source 21mAPower supply: internal NiMH rechargeable battery

 

 

Please see data sheet for full product specification  

If you have any problems or complaints of any nature please do not hesitate to contact us. Our staff will be more than happy to assist you and we guarantee a polite response and speedy resolution to all matters.

DESPATCH
Upon Clearance of full payment, and subject to availability and price checking, the ordered goods will be dispatched to the address quoted by the customer. We accept no liability for undelivered or mis-delivered items due to the customer supplying the incorrect delivery details.

Delivery Dates are given as accurately as possible but are not guaranteed. Under no circumstances will late delivery entitle the purchaser to reject the contract or to claim damages.

ITEMS OUT OF STOCK OR DELAYED DELIVERY
Customers will receive an email advising expected delivery dates, for such products.

ORDER CANCELLATION
If upon cancelling an order after it has been processed and/or dispatched a restocking fee may be charged.

SHIPPING LIABILITY & INCOTERMS
All products bought/hired from this website will be bought/hired; Ex-Works, for alternative delivery methods, please contact our Guisborough office on Telephone: +44 (0) 1287 204020 or by email at: sales@euremica.com.

We accept no liability for any damage or loss incurred by the customer or a third party due to carriage/delivery, late delivery, non delivery or any other circumstances no matter how such loss or damage was caused.

OWNERSHIP
Goods remain the property of Euremica Limited until payment has been received in full. (This excludes hire items)

RETURNS PROCEDURE
We understand that from time to time you may wish to return a product to us.
We have created this 14 day returns policy to enable you to return the products to us.

If you are in any way dissatisfied with the product you receive upon delivery we will be happy to exchange it for something more suitable, In order to take advantage of your rights under this returns policy. Please complete the following steps:

- You must Contact our Guisborough office, in writing, within 48 hours of delivery of the goods; Via Post; Euremica limited, Instrument House, Morgan Drive, Guisborough, Cleveland, TS14 7DG; or by email at: sales@euremica.com, giving full details of:
-  Reason for return (Listing any damages if any)
- Contact details to enable Euremica to Contact you, to arrange collections/replacements (if required)

- Goods must be returned back to Euremica within 14 days of delivery. (Don’t forget to include your goods returns note, so we can identify where the parcel has come from). Postage, re-stocking fees and/or suitable hire charges (if applicable) will be at the customers cost.

- Goods must be returned; unused, and in original packing.



- Goods will be inspected by Euremica Staff. If the goods are found to be damaged/unsuitable for resale, the cost of repair/replacement shall belong to the purchaser.

- Once inspected, instructions will be given to the customer outlining the relevant course of action (i.e.: replacement, repair, refund, new delivery dates etc).

-  If we are at fault in delivering your goods, for instance we dispatch the wrong item; we will resolve the problem as fast as is possible and cover all subsequent costs.

EXCLUSIONS
The following kinds of products may not be returned under this policy:
- Any products liable to deteriorate or perish subject to shelf life (i.e. gas sensors, - ALL hire items. Please refer to instructions listed in our terms & conditions of hire, and any subsequent delivery notes.

REFUNDS
We will give you a refund for the full price of any product properly returned by you in accordance with the terms of this returns policy excluding the original delivery charges and excluding the costs of returning the product to us).

Refunds will not be made until all merchandise is received back into Euremica in Good condition.

IMPROPER RETURNS
Where you return a product in contravention of this policy (and where you do not - We will not refund or exchange the product.
- We may retain the returned product until you pay to us such additional amount as we may charge for re-delivery of the returned product.

View Downloads
G.E Druck